UPTIG technology project
📂 Drawings
👤 RPLAY
Product Description
Working project of the UPTIG gas compressor station technology.
The unit is designed to prepare gas transported through the main gas pipeline for its use as fuel for gas turbine engines of gas pumping units, as pulse gas for controlling pneumatic valves of the compressor station and the connection unit, fuel gas for own needs.
Gas heaters and pulse gas receivers are mounted on an open site.
Gas cleaning filters, flow meters, UPIG, reducing lines of fuel gas and gas for own needs are mounted in the building.
Outdoor installation category for fire hazard - "An" according to NPB 107-97, explosion hazard zone class according to PUE - "B-1g".
Explosion and fire hazard category of the premises in the building - "A" according to NPB 105-95; explosion hazard zone class according to PUE - "B-1a".
The main gas pipelines of the plant belong to category "B" according to SNiP 2.05.06-85*, gas pipelines for own needs: with a pressure of 0.6 MPa - to high-pressure pipelines of category P, with a pressure of 0.3 MPa - to medium-pressure pipelines according to SNiP 42-01-2002.
File format: dwg, tif (AutoCAD 2010 is not editable)
Note: the original files of the *.tif format must be in the same folder with the project file *.dwg
Download the file "UPTIG Technology Project" >>>
Tags: gas compressor station, UPTIG
The unit is designed to prepare gas transported through the main gas pipeline for its use as fuel for gas turbine engines of gas pumping units, as pulse gas for controlling pneumatic valves of the compressor station and the connection unit, fuel gas for own needs.
Gas heaters and pulse gas receivers are mounted on an open site.
Gas cleaning filters, flow meters, UPIG, reducing lines of fuel gas and gas for own needs are mounted in the building.
Outdoor installation category for fire hazard - "An" according to NPB 107-97, explosion hazard zone class according to PUE - "B-1g".
Explosion and fire hazard category of the premises in the building - "A" according to NPB 105-95; explosion hazard zone class according to PUE - "B-1a".
The main gas pipelines of the plant belong to category "B" according to SNiP 2.05.06-85*, gas pipelines for own needs: with a pressure of 0.6 MPa - to high-pressure pipelines of category P, with a pressure of 0.3 MPa - to medium-pressure pipelines according to SNiP 42-01-2002.
File format: dwg, tif (AutoCAD 2010 is not editable)
Note: the original files of the *.tif format must be in the same folder with the project file *.dwg
Download the file "UPTIG Technology Project" >>>
Tags: gas compressor station, UPTIG
No Reviews Yet
Be the first to leave a review for this product!
Related Products
Ventilation and air conditioning symbols
Seller: RPLAY
ASB single line diagram
Seller: RPLAY
Starter Drawing
Seller: DSP_seller
Drawing caliper screw-cutting-machine
Seller: DSP_seller
Drawing Diagram of the power steering KAMAZ
Seller: DSP_seller
ASB Electrical
Seller: RPLAY
Water symbols
Seller: RPLAY
Project of the control room power supply system
Seller: RPLAY