Ventilation and heating of an apartment building
📂 Drawings
👤 RPLAY
Product Description
The project of ventilation and heating of an apartment building
Ventilation of the apartment house is forced-air with natural motivation. The inflow of air is unorganized, through open window panes and transoms. Exhaust ventilation of living rooms is provided through the exhaust channels of bathrooms and kitchens, which are located in brick walls. In the attic, the exhaust ducts are combined into prefabricated ventilators. Exhaust vents are removed to the roof. On the canals from the kitchens and bathrooms are installed adjustable grilles type P150.
The heating system of a residential building is vertical, single-tube, with a lower distribution of the coolant, flow-regulated. The supply and return pipelines of the heating system are laid along the technical ground. The supply and return pipelines of the heating system, laid along the technical ground, are covered with an anti-corrosion coating and are insulated with thermal insulation of the "Thermaflex" type. Cover for thermal insulation fiberglass roll PCT. The laying of the risers is open. Regulation of heat transfer of heating devices is carried out by thermoregulators of type RTD-G Danfoss.
Ventilation of the apartment house is forced-air with natural motivation. The inflow of air is unorganized, through open window panes and transoms. Exhaust ventilation of living rooms is provided through the exhaust channels of bathrooms and kitchens, which are located in brick walls. In the attic, the exhaust ducts are combined into prefabricated ventilators. Exhaust vents are removed to the roof. On the canals from the kitchens and bathrooms are installed adjustable grilles type P150.
The heating system of a residential building is vertical, single-tube, with a lower distribution of the coolant, flow-regulated. The supply and return pipelines of the heating system are laid along the technical ground. The supply and return pipelines of the heating system, laid along the technical ground, are covered with an anti-corrosion coating and are insulated with thermal insulation of the "Thermaflex" type. Cover for thermal insulation fiberglass roll PCT. The laying of the risers is open. Regulation of heat transfer of heating devices is carried out by thermoregulators of type RTD-G Danfoss.
No Reviews Yet
Be the first to leave a review for this product!
Related Products
Ventilation and air conditioning symbols
Seller: RPLAY
ASB single line diagram
Seller: RPLAY
Starter Drawing
Seller: DSP_seller
Drawing caliper screw-cutting-machine
Seller: DSP_seller
Drawing Diagram of the power steering KAMAZ
Seller: DSP_seller
ASB Electrical
Seller: RPLAY
Water symbols
Seller: RPLAY
Project of the control room power supply system
Seller: RPLAY